ACANORA Generator Interlock Kit Blue for Cutler Hammer CH and BR Series with Plug in Neutral Main 150 and 200 amp Panels, 1 1/4 - 1 7/16 Inch Spacing Between Main and Branch Breaker

2024-04-07 03:16:56







ACANORA Generator Interlock Kit Blue for Cutler Hammer CH and BR Series with Plug in Neutral Main 150 and 200 amp Panels, 1 1/4 - 1 7/16 Inch Spacing Between Main and Branch Breaker

ACANORA Generator Interlock Kit for Cutler Hammer CH and BR Series with Plug in Neutral Main 150 and 200 amp Panels Our interlock switch kit can prevent utility and generator power from being turned on at the same time.Our interlock kits in contrast to transfer switches, this kit does not require a separate generator breaker panel or special cover.The generator lock kit is made of heat-resistant and corrosion-resistant metal aluminum with surface oxidation treatment for long service life. Safety Interlock Switch Kit The generator interlock prevents utility and generator power from being turned on at the same time by sliding the interlock plate down and up.The breaker interlock kit allow you to deliver power from the generator to any circuit within the electrical panel. You can know which circuit breakers to close or keep on during a power outage.In case of power failure, the interlocking kit can become a lifeguard and safely guide the generator power to any circuit in your home so that you can use electricity normally. Please first measure the distance between main and generator breaker before purchasing The kit for Cutler Hammer CH and BR Series with Plug in Neutral Main 150 and 200 amp panels.Turn Down, the main breaker is on, generator break must be off.Turn Up, the generator break must be on, main breaker is off. For the detailed installation process, please refer to the ACANORA generator interlock kit installation video. Fit to Square D QO or Homeline Fit to General Electric GE Fit to Horizontal Main Cutler Hammer CH Series Interval Space Required 1-3/8 inch 1-1/4 inch 1-1/2 inch 150 or 200 amp Main Panels ✓ ✓ ✓

Product Features

  • Generator Interlock Kit Compatible with Cutler Hammer CH series and BR Series with plug in neutral main 150 and 200 amp panels, The separation between the main breaker and the generator breaker is 1 1/4 - 1 7/16 inches.
  • Interlock Kit is made of aluminum and then surface-oxidized to provide insulation, anti-corrosion and durable. easy to install, suitable for both indoor and outdoor generator boxes.
  • Generator lockout kit by sliding the lock plate up and down, easy to switch from grid supply or connect with a generator to power up all of your home electrical appliances, prevent utility and generator power from being turned on at the same time.
  • Breake Interlock Kit Blue x 1, Shoulder Screws x 3, Hex Nuts x 3, Generator Start-Up Procedure Label x 1, Remind Label x 5, Zip Ties x 2, Installation Manual x 1, 3/16 Drill Bit x 1.
  • ACANORA Interlock Switch Kit are backed by Lifetime warranty. Please feel free to contact us via Message if you have any question. Recommend to operate by licensed electricians.

Tags:workwarehouse

Title - Default Title

如果有任何关于网站的意见,可以QQ联系或者发邮箱。

tags - tags - tags - tags - tags - tags - tags - tags - tags - tags - tags - tags - tags - tags - tags -